The MultiCyclone was field tested on an outdoor swimming pool and the contents of its sediment chamber were laboratory tested. The laboratory test below revealed that the MultiCyclone was capable of trapping sediment between 10 to 100 microns.

The filtration efficiency of the MultiCyclone was tested by feeding 5 to 80 micron dust particles through the MultiCyclone and analyzing the percentage of dust particles trapped in the sediment chamber. The following laboratory tests revealed that the MultiCyclone was effective in filtering particles sized 40 to 80 microns.

DE powder was passed through the MultiCyclone to discover its effective flow rate. At 3 m3/hr, the MultiCyclone was able to remove approximately 60% of DE powder and at 21 m3/hr the MultiCyclone was able to remove 80% of DE powder.